U values for infill panels
The links below present tables with the middle point U value for different infill panels. The calculations are based on the requirements and general guidelines contained in the Swedish construction regulations BBR 2008, chapter 9.
Infill panel F2 – U value in the middle: 0.74 W/m2K
|
1,5 mm Aluminium sheet 4,8 mm Board 40 mm Insulation 4,8 mm Board 1,5 mm Aluminium sheet |
Infill panel F3 – U value in the middle: 0.74 W/m2K
|
1,5 mm Aluminium sheet 10 mm Chipboard 40 mm Insulation 1,5 mm Aluminium sheet |
Infill panel F4 – U value in the middle: 0.78 W/m2K
|
1,5 mm Aluminium sheet 40 mm Insulation 10 mm Sapa boarding |
Sapa Vaku Paneel
|
|
|
|
|
|
U value of infill panel Up W/m2K (middle point) |
|
Vaku Paneel Distance strip |
16 |
18 |
24 |
28 |
|
Panel thickness in mm |
20-28 |
20-28 |
31-38 |
31-38 |
U value of infill panel in W/m2K |
0,29 |
0,28 |
0,18 |
0,16 |
For more information please contact our Architect Support
|

| Surface layer: |
|
Glass, aluminium sheet and steel sheet are the standard materials |
| Colours: |
|
For glass and sheet metal according to RAL, NCS or DB (Akso Nobel) |
| Sizes: |
|
Min. 350x350 mm, Max. 2400x4500 mm |
| Noise reduction: |
|
Rw 42 dB for a glass and 3 mm sheet metal combination |
| Fire: |
|
Vaku Paneel is classified as non-flammable |