U values for infill panels

Only Vaku Paneel can be used as infill panels in the 5050 SG facade system. The middle point U values for infill panels are presented below. The calculations are based on the requirements and general guidelines contained in the Swedish construction regulations BBR 2008, chapter 9.



U value of infill panel Up W/m2K (middle point)
Vaku Paneel
distance strip
16
18
24
28
Panel thickness
in mm
26-28 26-28 31-35 31-35
U value of infill
panel in W/m2K
0,29 0,28 0,18 0,16
For more information please contact our Architect Support

Surface layer: Glass, aluminium sheet and steel sheet are the standard materials
Colours: For glass and sheet metal according to RAL, NCS or DB (Akso Nobel)
Sizes: Min. 350x350 mm, Max. 2400x4500 mm
Noise reduction: Rw 42 dB for a glass and 3 mm sheet metal combination
Fire: Vaku Paneel is classified as non-flammable
U value: From 0.29 to 0,29- 0,16 W/m2 K

Updated: 2010-03-24