Elegance 52 FR
|
EI30 / E30
|
|
In order to retain a uniform aesthetic treatment, Elegance 52 FR is based on the successful Elegance 52 ST concept and uses complementary profiles and accessories inside the system to make it fire resistant. Therefore, Elegance 52 ST and the fire resistant Elegance 52 FR version are visually indistinguishable. A combination of complementary intumescent strips, steel pressure plates, cooling materials and fire resistant glazing ensures the EI 30 classification. Both integrity and insulation are provided by the system. As a result, not only the fire itself, but also the heat is kept outside for at least 30 minutes.
Elegance 52 FR was tested officially to EN 1364-3, EN 1363-1 and EN 1363-2 for both internal and external fire-exposure.
|
| |
| |
| |
|
| |
Dimensions
|
| |
|
Sightline
|
|
52 mm |
|
| |
Mullion depth
|
|
41 - 273 mm |
|
| |
inertia (Ixx: wind)
|
|
9,57 - 1916,52 cm4 |
|
| |
Transom depth
|
|
22,5 - 199 mm |
|
| |
inertia (Ixx: wind)
|
|
3,67 - 515,84 cm4 |
|
| |
inertia (Iyy: glass)
|
|
1,09 - 53,03 cm4 |
|
| |
|
|
|
|
| |
|
|
|
|
Glazing
|
| |
| |
Infill thickness
|
|
4 - 50 mm |
|
| |
Glazing method
|
|
dry glazed with EPDM gaskets |
|
| |
|
|
|
|
| |
|
|
|
|
Performance
|
| |
| |
Thermal break
|
|
4 - 36 mm (Isolator)
|
|
| |
Thermal insulation
EN ISO 10077-2
|
|
Ucw < 1,4 W/m2K with glass Ug = 1,1 W/m2K |
|
| |
|
|
|
|
| |
Air permeability
|
AE750
|
EN 12152 |
|
| |
Water tightness
|
RE 750 |
EN 12154 |
|
| |
Wind resistance
|
3000 Pa |
EN 13116 |
|
| |
|
|
|
|
| |
|
|
|
|
Acoustics:
|
| |
| |
with Glas 6/15/4
|
|
Rw(C;Ctr) = 34(0;-2)dB |
|
| |
with Glas 10/15/6
|
|
Rw(C;Ctr) = 36(-1;-2)dB |
|
| |
with Glas 12/16/44.2
|
|
Rw(C;Ctr) = 42(-2;-5)dB |
|
| |
|
|
|
|
| |
Impact test
|
class 5 |
EN14019 |
|
| |
|
|
|
|
| |
|
|
|
|
| |
|
|
|
|